Dr Peter J Shaw: Clinical Services, Optometric Software, Diagnostic Instrumentation, Education and Research 877 796 9944 | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
For PatientsFor Eye Care Professionals |
Developed by at the Scarborough Low Vision Centre, the Opsis family of vision assessment systems meets the needs of primary care practitioners, low vision specialists, binocular vision specialists, researchers and outreach programmes. Opsis measures stereopsis, fixation disparity, contrast sensitivity, visual acuity, vernier acuity and is a primary ally in the differential diagnosis of ocular pathologies and the assessment of vision function. Opsis has unique features to reduce chair time and enhance diagnostic skills
OpsisLite: An economical alternative for the primary care optometrist and physician |
![]() |
Only computer based vision tests or printed charts conform to the brightness and contrast mandated by the WHO. Compare the contrast and brightness of Opsis displayed on a 19" LCD monitor and an AO projector with a halogen upgrade. Replace that antiquated projector with its reduced screen contrast, dusty slides and delicate screen allows you to take acuities with the lights on for improved efficiency and patient comfort. |
| Features and specifications | OpsisLite | OpsisEMR | OpsisLV |
| Scale | ft, metres | ft, metres, logMAR | ft, metres, logMAR |
| Optotypes | 3 | 8 | 8 |
| Test distance | 6-30' | 6-30' | 6'-30' |
| Mirrored exam lane | yes | yes | yes |
| Acuity (monitor & distance dependent) | 20/10-20/800 | 20/10-20/800 | 20/13-20/1600 |
| Presentation | ETDRS | ETDRS, AO | ETDRS |
| Format | Sloan, Allen | Sloan, Bailey Lovie, Allen | Sloan, Bailey Lovie |
| Reverse contrast , blue/yellow | no | yes | yes |
| Random letter contrast sensitivity (logCS .0.10 to 2.00) | 20/200 | 20/70, 20/200, | 20/200, 20/400,20/800 |
| 10% contrast ETDRS | no | yes | yes |
| Spatial frequency contrast sensitivity (0.40 to 2.20) | no | 1.5,3,6,12,18 cycles per degree | same |
| Macular function test and central field mapping | no | no | yes |
| Output/Storage | no | record, graph and print | yes |
| Mesopic contrast sensitivity | no | yes | yes |
| Fixation disparity | no | Mallett boxes (vert/hor) variable | yes |
| Stereo acuity | no | Howard Dolman to 20" random | yes |
| Worth dot | no | yes, adjustable size | yes |
| Light/Dark room strategies for anaglyph targets | no | yes | yes |
| Animated fixation target | yes | yes, adjustable size | yes |
| Masking | no | yes | yes |
| Crowding bars (WHO design) | no | yes | yes |
| Bichrome | yes | yes | yes |
| Vernier acuity | no | yes , adjustable | yes |
| Power blocks for cylinder | no | yes, rotatable | yes |
| Fan dial | no | yes, rotatable | yes |
| Jackson cross cyl. target with acuity | yes | yes, adjustable | yes |
| Amsler grid | no | yes, size adjustable | yes |
| Colour vision screening | no | yes | yes |
| Control via | mouse | keypad, keyboard | keyboard, keypad, mouse |
| Simplified Cursor Arrow Control | yes | yes | yes |
| Programmable hot keys | no | yes | yes |
| Direct access acuity | no | yes | yes |
| Third party software integration/communication | no | yes | yes |
| Records and store acuity, contrast sensitivity | no | yes | yes |
| Network compatible | no | yes | yes |
| Suitable for screenings and outreach services | yes | yes | yes |
| Auto calibration | yes | yes | yes |
| Windows 98.2000.XP,Vista compatible | yes | yes | yes |